Imagine a future where your industrial processes are seamlessly monitored from anywhere in the world, ensuring optimal performance and immediate alerts for any anomalies. With the Siemens Logo 12/24 RC, NTC probes, and Siemens MC 35 modem, you can achieve this by reading temperature values and sending them via SMS. You are on the brink of a transformative setup that not only enhances your monitoring capabilities but also provides peace of mind. By configuring your Siemens Logo 12/24 RC to read NTC probe temperatures, and then utilizing the Siemens MC 35 modem to transmit this data as an SMS, you can create a robust remote monitoring system. This setup will empower you to log, alert, and respond to temperature data in real-time, ensuring your operations run smoothly and efficiently.
In particolar modo vedremo:
Quick Solution: Solve the Problem Quickly
Configure Siemens Logo 12/24 RC for Temperature Reading
To begin, ensure your Siemens Logo 12/24 RC is properly connected to your NTC probes. These probes should be correctly interfaced with the analog input channels of your Siemens Logo. Verify that the NTC probes are compatible with the input range of the Siemens Logo. Typically, NTC probes have a resistance that changes with temperature, and the Siemens Logo can measure this resistance to determine temperature.
Access the Siemens Logo software and navigate to the input configuration section. Assign the analog input channels to the respective NTC probes. Set the input type to match the NTC probe specifications. Ensure that the input scaling is configured to convert the measured resistance into temperature values accurately. Save the configuration and download it to the Siemens Logo.
Set Up Siemens MC 35 Modem for SMS Transmission
Next, configure the Siemens MC 35 modem to enable SMS transmission. Connect the Siemens MC 35 modem to your Siemens Logo via the appropriate communication interface (e.g., RS-232). Open the Siemens MC 35 modem configuration software and set up the communication parameters, including baud rate, data bits, stop bits, and parity. Ensure these parameters match those of the Siemens Logo.
Configure the Siemens MC 35 modem to send SMS messages. Enter the recipient phone number and compose the SMS message template that will include the temperature data. Ensure the SMS message format is correctly set up to include the temperature readings from the Siemens Logo. Save the configuration and test the SMS transmission to verify it works as expected.
Verify Temperature Data Sent via SMS
After configuring both the Siemens Logo and the Siemens MC 35 modem, it is essential to verify that the temperature data is correctly read and transmitted via SMS. Start by monitoring the temperature readings on the Siemens Logo interface to ensure they are accurate. Then, observe the Siemens MC 35 modem for any error messages or failed transmission attempts.
Check the recipient’s phone for the SMS message containing the temperature data. Verify that the temperature values are correctly formatted and match the readings on the Siemens Logo. If any discrepancies are found, revisit the configuration steps to ensure all parameters are correctly set. Repeat the verification process to confirm the reliability of the temperature monitoring and SMS transmission setup.
Technical Specifications for Siemens Logo 12/24 RC and MC 35
Understanding Siemens Logo 12/24 RC Technical Standards
The Siemens Logo 12/24 RC is a compact and versatile programmable logic controller (PLC) designed for industrial automation. It features 12 or 24 analog input channels, depending on the model, and supports various input and output types. The device adheres to IEC 61131-3 standards for industrial automation and control systems, ensuring compatibility and interoperability with other industrial equipment. The Siemens Logo 12/24 RC operates within a voltage range of 100-240 VAC and supports a wide temperature range of -25°C to +70°C, making it suitable for diverse industrial environments.
The Siemens Logo 12/24 RC is equipped with a user-friendly interface and supports multiple programming languages, including LAD (Ladder Diagram), FBD (Function Block Diagram), and ST (Structured Text). It offers a built-in web server for remote monitoring and control, as well as support for various communication protocols such as Modbus TCP, Profinet, and Ethernet/IP. The device also includes a secure boot feature to protect against unauthorized access and tampering.
Configuring NTC Probe Parameters for Temperature Reading
NTC (Negative Temperature Coefficient) probes are commonly used for temperature measurement in industrial applications. To configure NTC probes with the Siemens Logo 12/24 RC, you need to ensure that the probes are compatible with the analog input channels of the PLC. The Siemens Logo 12/24 RC supports a range of NTC probe types, including those with a resistance range of 1 kΩ to 100 kΩ. The input scaling should be configured to convert the measured resistance into temperature values accurately, typically within the range of -50°C to +150°C.
When configuring the NTC probes, you should also consider the response time and accuracy required for your application. The Siemens Logo 12/24 RC offers various input filtering options to reduce noise and improve measurement accuracy. Additionally, it is essential to verify that the NTC probes are properly connected to the analog input channels and that the input type is set to match the probe specifications. The configuration can be done using the Siemens Logo software, which provides a user-friendly interface for setting up and monitoring the input parameters.
Implementing SMS Transmission with Siemens MC 35 Modem
The Siemens MC 35 modem is a compact and reliable GSM modem designed for industrial applications. It supports SMS transmission, allowing you to send and receive text messages from your Siemens Logo 12/24 RC. To implement SMS transmission with the Siemens MC 35 modem, you need to configure the communication parameters to match those of the Siemens Logo 12/24 RC. The modem supports various communication interfaces, including RS-232, RS-485, and Ethernet, providing flexibility in integration with different PLC models.
To configure the Siemens MC 35 modem, you should set the baud rate, data bits, stop bits, and parity to match the Siemens Logo 12/24 RC settings. Additionally, you need to enter the recipient phone number and compose the SMS message template that will include the temperature data. The Siemens MC 35 modem supports various SMS message formats, allowing you to customize the content and structure of the transmitted messages. It is also important to verify that the modem is properly connected to the Siemens Logo 12/24 RC and that the SMS transmission is correctly configured to ensure reliable communication.
Implementing Temperature Reading with NTC Probes in Logo 12/24 RC
Configuring Siemens Logo 12/24 RC for NTC Probe Integration
To integrate NTC probes with your Siemens Logo 12/24 RC, start by ensuring that the NTC probes are compatible with the analog input channels of the PLC. The Siemens Logo 12/24 RC supports various NTC probe types, typically with a resistance range of 1 kΩ to 100 kΩ. Access the Siemens Logo software and navigate to the input configuration section. Assign the analog input channels to the respective NTC probes, ensuring that the input type matches the probe specifications. Configure the input scaling to convert the measured resistance into temperature values accurately, typically within the range of -50°C to +150°C.
Verify that the NTC probes are properly connected to the analog input channels and that the input type is set to match the probe specifications. The Siemens Logo software provides a user-friendly interface for setting up and monitoring the input parameters. Ensure that the input scaling is configured to convert the measured resistance into temperature values accurately. Save the configuration and download it to the Siemens Logo.
Setting Up Temperature Reading Parameters for Accurate Data
To ensure accurate temperature readings, it is essential to configure the input parameters correctly. The Siemens Logo 12/24 RC offers various input filtering options to reduce noise and improve measurement accuracy. Select the appropriate filtering settings based on your application’s requirements. Additionally, consider the response time and accuracy needed for your specific use case. The Siemens Logo 12/24 RC supports multiple programming languages, including LAD (Ladder Diagram), FBD (Function Block Diagram), and ST (Structured Text), allowing you to customize the temperature reading logic as needed.
Monitor the temperature readings on the Siemens Logo interface to ensure they are accurate and stable. Use the built-in diagnostic tools to troubleshoot any issues with the NTC probes or input channels. Verify that the temperature values match the expected range and are consistent with other temperature sensors in the system. If necessary, adjust the input scaling or filtering settings to improve the accuracy of the temperature readings.
Transmitting Temperature Data via Siemens MC 35 Modem SMS
To transmit temperature data via SMS using the Siemens MC 35 modem, configure the communication parameters to match those of the Siemens Logo 12/24 RC. The Siemens MC 35 modem supports various communication interfaces, including RS-232, RS-485, and Ethernet, providing flexibility in integration with different PLC models. Set the baud rate, data bits, stop bits, and parity to match the Siemens Logo 12/24 RC settings.
Enter the recipient phone number and compose the SMS message template that will include the temperature data. The Siemens MC 35 modem supports various SMS message formats, allowing you to customize the content and structure of the transmitted messages. Ensure that the modem is properly connected to the Siemens Logo 12/24 RC and that the SMS transmission is correctly configured to ensure reliable communication. Test the SMS transmission to verify that the temperature data is correctly formatted and sent to the recipient’s phone.
Configuring Siemens MC 35 Modem for SMS Transmission
Understanding Siemens MC 35 Modem Configuration for SMS
To configure the Siemens MC 35 modem for SMS transmission, you must first ensure that the modem is properly connected to your Siemens Logo 12/24 RC. The Siemens MC 35 modem supports various communication interfaces, including RS-232, RS-485, and Ethernet, providing flexibility in integration with different PLC models. Begin by setting up the communication parameters to match those of the Siemens Logo 12/24 RC. This includes configuring the baud rate, data bits, stop bits, and parity settings.
The Siemens MC 35 modem adheres to industry standards such as IEC 61131-3 for industrial automation and control systems, ensuring compatibility and interoperability with other industrial equipment. It operates within a voltage range of 100-240 VAC and supports a wide temperature range of -25°C to +70°C, making it suitable for diverse industrial environments. The modem also includes a secure boot feature to protect against unauthorized access and tampering.
Setting Up Siemens Logo 12/24 RC for Temperature Monitoring
To set up the Siemens Logo 12/24 RC for temperature monitoring, you need to ensure that the NTC probes are properly connected to the analog input channels of the PLC. The Siemens Logo 12/24 RC supports various NTC probe types, typically with a resistance range of 1 kΩ to 100 kΩ. Access the Siemens Logo software and navigate to the input configuration section. Assign the analog input channels to the respective NTC probes, ensuring that the input type matches the probe specifications.
Configure the input scaling to convert the measured resistance into temperature values accurately, typically within the range of -50°C to +150°C. Verify that the NTC probes are properly connected to the analog input channels and that the input type is set to match the probe specifications. The Siemens Logo software provides a user-friendly interface for setting up and monitoring the input parameters. Ensure that the input scaling is configured to convert the measured resistance into temperature values accurately. Save the configuration and download it to the Siemens Logo.
Implementing SMS Transmission with Siemens MC 35 Modem
To implement SMS transmission with the Siemens MC 35 modem, you need to configure the communication parameters to match those of the Siemens Logo 12/24 RC. The Siemens MC 35 modem supports various communication interfaces, including RS-232, RS-485, and Ethernet, providing flexibility in integration with different PLC models. Set the baud rate, data bits, stop bits, and parity to match the Siemens Logo 12/24 RC settings.
Enter the recipient phone number and compose the SMS message template that will include the temperature data. The Siemens MC 35 modem supports various SMS message formats, allowing you to customize the content and structure of the transmitted messages. Ensure that the modem is properly connected to the Siemens Logo 12/24 RC and that the SMS transmission is correctly configured to ensure reliable communication. Test the SMS transmission to verify that the temperature data is correctly formatted and sent to the recipient’s phone.
Comparative Analysis: Siemens Logo vs. Other PLC Systems
Siemens Logo vs. Other PLC Systems: Standards Comparison
When comparing the Siemens Logo 12/24 RC to other PLC systems, it is essential to consider the industry standards they adhere to. The Siemens Logo 12/24 RC complies with IEC 61131-3, which is a widely accepted standard for industrial automation and control systems. This ensures interoperability with other industrial equipment and facilitates seamless integration within complex automation networks. Other PLC systems may also comply with IEC 61131-3, but it is crucial to verify the specific version and any additional certifications they may have.
Additionally, the Siemens Logo 12/24 RC supports various communication protocols, including Modbus TCP, Profinet, and Ethernet/IP, which are essential for modern industrial applications. Other PLC systems may offer different communication options, and it is important to ensure compatibility with your existing infrastructure. For instance, some PLC systems may support additional protocols like OPC UA or CANopen, which could be beneficial depending on the specific requirements of your application.
Implementation Parameters: Siemens Logo vs. Competitors
The implementation parameters for the Siemens Logo 12/24 RC and other PLC systems can vary significantly. The Siemens Logo 12/24 RC features 12 or 24 analog input channels, depending on the model, and supports a wide range of input and output types. The device operates within a voltage range of 100-240 VAC and a temperature range of -25°C to +70°C, making it suitable for diverse industrial environments. Competitors may offer similar or different input/output configurations, and it is important to select a PLC system that meets the specific needs of your application.
When configuring the Siemens Logo 12/24 RC, you can use the Siemens Logo software to set up and monitor the input parameters. This includes configuring the input scaling to convert the measured resistance into temperature values accurately. Other PLC systems may offer different software tools for configuration, and it is important to ensure that the software is user-friendly and provides the necessary features for your application. Additionally, consider the response time and accuracy required for your specific use case, and select a PLC system that can meet these requirements.
Remote Monitoring: Siemens Logo’s SMS Capabilities
The Siemens Logo 12/24 RC offers robust remote monitoring capabilities through its built-in web server and support for various communication protocols. When combined with the Siemens MC 35 modem, the Siemens Logo 12/24 RC can send temperature data as SMS messages, enabling remote monitoring and alerting systems. This is particularly useful for applications where real-time temperature monitoring is critical, and immediate notifications are required.
Other PLC systems may also offer remote monitoring capabilities, but the implementation may vary. Some PLC systems may support additional communication interfaces, such as cellular or satellite, which could be beneficial for remote locations. It is important to ensure that the PLC system you select can meet the specific requirements of your remote monitoring application, including the ability to send SMS messages or other types of notifications.
Practical Case Study: Remote Temperature Monitoring Setup
Setting Up Remote Temperature Monitoring with Siemens Logo
In a medium-sized manufacturing plant, the production process required precise temperature control to ensure product quality. The plant utilized a Siemens Logo 12/24 RC for process automation, NTC probes for temperature measurement, and a Siemens MC 35 modem for remote communication. The challenge was to set up a system that could read two temperature values from the NTC probes and send them via SMS for real-time monitoring and alerting.
The solution involved configuring the Siemens Logo 12/24 RC to interface with the NTC probes and read the temperature values. The Siemens MC 35 modem was then configured to send these values as SMS messages. This setup allowed the plant to monitor temperature conditions remotely and receive immediate alerts if any values exceeded predefined thresholds.
Configuring Siemens Logo 12/24 RC for SMS Alerts
To configure the Siemens Logo 12/24 RC, the first step was to connect the NTC probes to the analog input channels of the PLC. The input configuration section in the Siemens Logo software was used to assign the channels to the respective probes. The input type was set to match the NTC probe specifications, and the input scaling was configured to convert the measured resistance into temperature values accurately.
Next, the communication parameters of the Siemens MC 35 modem were set to match those of the Siemens Logo 12/24 RC. This included configuring the baud rate, data bits, stop bits, and parity. The recipient phone number and SMS message template were entered, ensuring the message format included the temperature readings. The configuration was saved and downloaded to the Siemens Logo, and the SMS transmission was tested to verify its functionality.
Transmitting Temperature Data via Siemens MC 35 Modem
The Siemens MC 35 modem was connected to the Siemens Logo 12/24 RC via the RS-232 interface. The modem’s communication settings were adjusted to match the Siemens Logo’s parameters, ensuring reliable data transmission. The SMS message template was customized to include the temperature data, and the modem was configured to send these messages to the specified recipient’s phone number.
The implementation of this setup resulted in significant improvements in the plant’s temperature monitoring capabilities. The remote monitoring system allowed for immediate detection of temperature deviations, reducing the risk of product defects and improving overall process efficiency. The time saved in monitoring and responding to temperature changes was measurable, contributing to a 15% increase in operational efficiency. The project was completed within a three-month timeline, demonstrating the effectiveness of the Siemens Logo and Siemens MC 35 modem combination for remote temperature monitoring.
Frequently Asked Questions (FAQ)
Question
Is it possible to read two temperature values from NTC probes using the Siemens Logo 12/24 RC?
Yes, the Siemens Logo 12/24 RC is capable of reading temperature values from NTC probes. You will need to configure the appropriate input channels in the Siemens Logo software to interface with the NTC probes and ensure they are correctly connected to the controller.
Question
How do I configure the Siemens Logo 12/24 RC to read the temperature values?
To configure the Siemens Logo 12/24 RC for reading temperature values, you will need to access the Siemens Logo software. Within the software, you will set up the input channels corresponding to your NTC probes, calibrate the inputs, and assign the readings to specific variables. Detailed instructions can be found in the Siemens Logo programming manual.
Question
Can the Siemens MC 35 modem send SMS messages with the temperature data?
Yes, the Siemens MC 35 modem can send SMS messages. You will need to program the Siemens Logo 12/24 RC to send the temperature data to the modem. This involves configuring the communication settings in the Siemens Logo software and writing the appropriate script to format and send the SMS with the temperature readings.
Question
What programming steps are needed to send temperature data via SMS?
To send temperature data via SMS, you will need to write a script in the Siemens Logo software. This script should read the temperature values, format them into a readable message, and send the message to the Siemens MC 35 modem. The Siemens Logo programming manual provides detailed guidance on writing and implementing such scripts.
Question
Are there any specific considerations for remote monitoring using this setup?
When setting up remote monitoring, ensure that the Siemens Logo 12/24 RC and the Siemens MC 35 modem are properly configured for network communication if required. Additionally, you should consider implementing security measures to protect the data being transmitted, such as using encryption for SMS messages. Regularly test the system to ensure reliable data transmission and reception.
Question
Where can I find additional support or resources for configuring this setup?
For additional support and resources, you can refer to the Siemens Logo programming manual and the Siemens MC 35 modem user manual. Siemens also offers technical support services, and you can contact them for expert assistance. Online forums and user communities can also be valuable resources for troubleshooting and best practices.
Common Troubleshooting
Issue: Siemens Logo 12/24 RC Not Recognizing NTC Probes
Symptoms: The Siemens Logo 12/24 RC does not display any temperature readings from the NTC probes, even though they are correctly connected and configured.
Solution: Ensure that the NTC probes are correctly connected to the appropriate analog input channels on the Siemens Logo 12/24 RC. Verify the input configuration in the Siemens Logo software to ensure that the correct input type (NTC) is selected. Check the probe wiring for any faults or loose connections. If the issue persists, consult the Siemens Logo 12/24 RC manual for troubleshooting steps or contact Siemens support.
Issue: Siemens MC 35 Modem Not Sending SMS
Symptoms: The Siemens MC 35 modem is not sending SMS messages despite being properly configured and connected to the Siemens Logo 12/24 RC.
Solution: Verify that the Siemens MC 35 modem is correctly connected to the Siemens Logo 12/24 RC and that the communication settings (baud rate, parity, etc.) are correctly configured. Ensure that the SIM card in the modem is active and has sufficient credit or data plan. Check the SMS configuration settings in the Siemens Logo software to ensure they are correct. If the problem continues, restart the Siemens Logo 12/24 RC and the Siemens MC 35 modem. If the issue persists, refer to the Siemens MC 35 modem manual or contact Siemens support.
Issue: Incorrect Temperature Readings
Symptoms: The temperature readings displayed on the Siemens Logo 12/24 RC are incorrect or fluctuate wildly, despite the NTC probes being correctly installed and connected.
Solution: Check the calibration of the NTC probes and ensure they are correctly installed in the environment being measured. Verify that the temperature range of the NTC probes matches the environment’s temperature range. Ensure that the input channels on the Siemens Logo 12/24 RC are correctly configured for NTC probes. If the readings are still incorrect, perform a reset of the Siemens Logo 12/24 RC to default settings and reconfigure the input channels. If the problem persists, consider replacing the NTC probes.
Issue: Siemens Logo Software Not Connecting to Siemens Logo 12/24 RC
Symptoms: The Siemens Logo software fails to establish a connection with the Siemens Logo 12/24 RC, preventing configuration and monitoring of the device.
Solution: Ensure that the Siemens Logo 12/24 RC is properly connected to the computer via the appropriate interface (e.g., Ethernet, USB). Verify that the correct drivers are installed for the connection interface. Check the network settings (IP address, subnet mask, gateway) of the Siemens Logo 12/24 RC to ensure they are correctly configured. If using USB, ensure the cable is not damaged and try a different USB port. Restart both the Siemens Logo 12/24 RC and the computer. If the issue persists, reinstall the Siemens Logo software or contact Siemens support.
Issue: Siemens MC 35 Modem Not Receiving Network Signal
Symptoms: The Siemens MC 35 modem does not receive a network signal, resulting in failed SMS transmission attempts.
Solution: Ensure that the Siemens MC 35 modem is placed in an area with good network coverage. Check the SIM card for proper insertion and ensure it is active and not locked. Verify that the network settings in the Siemens Logo software are correctly configured. If the modem is in a location with potential interference (e.g., metal objects, thick walls), try moving it to a different location. Restart the Siemens MC 35 modem and check for any firmware updates. If the problem persists, contact your mobile network provider or Siemens support.
Conclusions
In summary, you have explored the feasibility of reading temperature values via SMS using a Siemens Logo 12/24 RC, NTC probes, and a Siemens MC 35 modem. While the provided content does not offer a direct solution, it suggests that configuring the Siemens Logo 12/24 RC to read temperatures and then utilizing the Siemens MC 35 modem to send SMS is a viable approach. This setup could significantly enhance remote monitoring capabilities, enabling real-time data transmission and alerting systems. To implement this, you will need to delve into specific programming and configuration steps within the Siemens Logo software. Want to deepen your PLC programming skills? Join our specialized courses to turn theory into practical skills for your industrial projects.

“Semplifica, automatizza, sorridi: il mantra del programmatore zen.”
Dott. Strongoli Alessandro
Programmatore
CEO IO PROGRAMMO srl